Central versus peripheral cannulation for acute type A aortic dissection.

Yousef, Sarah; Brown, James A; Serna-Gallegos, Derek; Navid, Forozan; Zhu, Jianhui; Thoma, Floyd W; Bianco, Valentino; Aranda-Michel, Edgar et al. · J Thorac Cardiovasc Surg · 2024

retrospective_cohort · Level III

Where this comes from

Abstract

This study sought to evaluate the impact of central aortic versus peripheral cannulation on outcomes after acute type A aortic dissection repair. This was an observational study using an institutional database of acute type A aortic dissection repairs from 2007 to 2021. Patients were stratified according to central, subclavian, or femoral cannulation. Kaplan-Meier survival estimation and multivariable Cox regression were performed. The study population consisted of 577 patients who underwent acute type A aortic dissection repair. Of these, central cannulation was used in 490 patients (84.9%), subclavian cannulation was used in 54 patients (9.4%), and femoral cannulation was used in 33 patients (5.7%). Rates of peripheral vascular disease, aortic insufficiency moderate or greater, and cerebral malperfusion differed significantly among the groups, but baseline characteristics were otherwise comparable (P > .05). Operative mortality was lowest in the central cannulation group (9.8%), but this did not differ significantly among the groups. Kaplan-Meier survival estimates were similar among the groups. On multivariable Cox regression, cannulation strategy was not significantly associated with long-term survival. Acute type A aortic dissection repair can be safely performed through central aortic cannulation, with outcomes comparable to those obtained with subclavian or femoral cannulation.

Medical subject headings