Artificial Intelligence-Aided Colonoscopy Does Not Increase Adenoma Detection Rate in Routine Clinical Practice.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 36001408.
- Also identified by DOI 10.14309/ajg.0000000000001970.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The performance of artificial intelligence-aided colonoscopy (AIAC) in a real-world setting has not been described. We compared adenoma and polyp detection rates (ADR/PDR) in a 6-month period before (pre-AIAC) and after introduction of AIAC (GI Genius, Medtronic) in all endoscopy suites in our large-volume center. The ADR and PDR in the AIAC group was lower compared with those in the pre-AIAC group (30.3% vs 35.2%, P < 0.001; 36.5% vs 40.9%, P = 0.004, respectively); procedure time was significantly shorter in the AIAC group. In summary, introduction of AIAC did not result in performance improvement in our large-center cohort, raising important questions on AI-human interactions in medicine.
Medical subject headings
- Colonic Polyps
- Adenoma
- Adenomatous Polyps
- Colorectal Neoplasms