Technical Trick: Supplemental Medial Column Screw Fixation of Distal Femur Fractures Treated With a Laterally Based Locked Plate.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 36001898.
- Also identified by DOI 10.1097/BOT.0000000000002475.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Given known failure rates after lateral plating of distal femur fractures, there is an increasing interest in augmenting fixation to improve outcomes. The addition of medial plates or intramedullary nails have been described with promising results, decreasing nonunion and varus collapse rates. However, the use of dual implants increases implant costs, adds surgical complexity, and requires a second surgical approach that may increase morbidity. A supplemental, percutaneously placed, medial column screw may provide a less invasive means of improving stability and achieving fracture union compared with lateral plating alone.