Recurvatum Deformity in Proximal Tibial Fractures Treated With the Synthes Tibial Nail.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 36067047.
- Also identified by DOI 10.3928/01477447-20220831-03.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Sagittal malalignment after intramedullary fixation of proximal third tibial shaft fractures has been described frequently, but almost every reported case involves a procurvatum deformity. We report 2 cases of recurvatum deformity of proximal third tibial shaft fractures where the Synthes EX tibial nail was used. The recurvatum deformity may have been induced by the shape of the nail, with its more distal Herzog curve relative to designs from other manufacturers. In proximal third tibial shaft fractures, tibial nails with distal Herzog curves may induce a recurvatum deformity that is not easily correctable. [<i>Orthopedics</i>. 2023;46(2):e129-e131.].
Medical subject headings
- Fracture Fixation, Intramedullary
- Tibial Fractures
Anatomy
- tibia