Miniplate and K-Wire Fixation for Type Vb Jersey Finger: A Case Series of Nine Patients.

Li, Bin; Yang, Yong; Li, Feng; Huang, Xingjian; Cao, Mengqi; Yin, Yaobin · J Hand Surg Am · 2024

case_series · Level IV

Where this comes from

Abstract

The aim of this study was to present the results of plate and K-wire fixation for type Vb jersey finger. We used a miniplate system combined with a K-wire to treat nine cases of acute type Vb jersey finger injury. The fracture healing time, functional outcomes, and complications were assessed. The follow-up time ranged from 13 to 44 months. All fractures healed within 7 weeks. The mean active range of motion was 70.6° (60° to 80°) for the distal interphalangeal joint and 105° (100° to 110°) for the proximal interphalangeal joint. All affected fingers were able to move actively with no pain, and there was no nail deformity. Two patients with the longest radiographic follow-up showed a congruent joint surface with no degenerative change at 44 months. Miniplate and K-wire fixation offers adequate fixation strength for the early initiation of active exercises so that a good functional result can be achieved. Therapeutic V.