Intraindividual Comparison of Contrast-Enhanced Ultrasound Using Perfluorobutane With Modified Criteria Versus CT/MRI LI-RADS Version 2018 for Diagnosing HCC in High-Risk Patients.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 36382914.
- Also identified by DOI 10.2214/AJR.22.28420.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
<b>BACKGROUND.</b> Previously proposed modifications to LI-RADS criteria for contrast-enhanced ultrasound (CEUS) performed using perfluorobutane contrast agent yielded increased sensitivity for hepatocellular carcinoma (HCC) without a significant decrease in specificity. <b>OBJECTIVE.</b> The purpose of our study was to compare the diagnostic performance of CEUS with perfluorobutane using modified LI-RADS criteria versus contrast-enhanced CT or MRI using LI-RADS version 2018 (v2018) for characterizing lesions as HCC in high-risk patients. <b>METHODS.</b> This retrospective study included 171 patients (140 men, 31 women; mean age, 54 ± 12 [SD] years) at high-risk for HCC with a pathologically confirmed liver observation evaluated by both CEUS using perfluorobutane and contrast-enhanced CT or MRI between March 2020 and May 2021. A matching algorithm was used to select two patients with HCC for each patient with a non-HCC lesion. Two readers evaluated observations using previously proposed modifications to CEUS LI-RADS version 2017 that classify certain observations as LR-5 rather than as LR-4 or LR-M on the basis of the presence of Kupffer phase defect after perfluorobutane administration; two different readers evaluated observations using CT/MRI LI-RADS v2018. Each reader pair reached consensus. Diagnostic performance was evaluated. <b>RESULTS.</b> A total of 114 patients had HCC, 43 had a non-HCC malignancy, and 14 had a benign lesion. Modified CEUS criteria using perfluorobutane and CT/MRI LI-RADS v2018 showed no significant difference (<i>p</i> > .05) in sensitivity (92.1% vs 89.5%), specificity (87.7% vs 84.2%), or accuracy (90.6% vs 87.7%) of LR-5 for diagnosis of HCC. Of six observations assessed as LR-4 only by CT/MRI LI-RADS v2018, modified CEUS criteria using perfluorobutane assessed one as LR-3 (benign lesion) and five as LR-5 (all HCC). Of seven observations assessed as LR-M only by CT/MRI LI-RADS v2018, modified CEUS criteria using perfluorobutane assessed one as LR-3 (non-HCC malignancy) and six as LR-5 (all HCC). Eight of 12 observations assessed as LR-5 only by CT/MRI LI-RADS v2018 and 11 of 13 observations assessed as LR-5 only by modified CEUS criteria using perfluorobutane were HCC. <b>CONCLUSION.</b> The diagnostic performance of LR-5 for HCC diagnosis was not significantly different between modified CEUS criteria using perfluorobutane and CT/MRI LI-RADS v2018. <b>CLINICAL IMPACT.</b> The findings support the application of modified CEUS criteria using perfluorobutane for diagnosing HCC in high-risk patients.
Medical subject headings
- Carcinoma, Hepatocellular
- Liver Neoplasms