Detection and size measurements of kidney stones on virtual non-contrast reconstructions derived from dual-layer computed tomography in an ex vivo phantom setup.

Reimer, R P; Zaytoun, H; Klein, K; Sonnabend, K; Lennartz, S; Zopfs, D; Heidenreich, A; Maintz, D et al. · Eur Radiol · 2023

basic_science · Level V

Where this comes from

Abstract

To systematically investigate the usability of virtual non-contrast reconstructions (VNC) derived from dual-layer CT (DLCT) for detection and size measurements of kidney stones with regards to different degrees of surrounding iodine-induced attenuation and radiation dose. Ninety-two kidney stones of varying size (3-14 mm) and composition were placed in a phantom filled with different contrast media/water mixtures exhibiting specific iodine-induced attenuation (0-1500 HU). DLCT-scans were acquired using CTDI<sub>vol</sub> of 2 mGy and 10 mGy. Conventional images (CI) and VNC<sub>0H-1500HU</sub> were reconstructed. Reference stone size was determined using a digital caliper (Man-M). Visibility and stone size were assessed. Statistical analysis was performed using the McNemar test, Wilcoxon test, and the coefficient of determination. All stones were visible on CI<sub>0HU</sub> and VNC<sub>200HU</sub>. Starting at VNC<sub>400 HU</sub>, the detection rate decreased with increasing HU and was significantly lower as compared to CI<sub>0HU</sub> on VNC<sub>≥ 600HU</sub> (100.0 vs. 94.0%, p < 0.05). The overall detection rate was higher using 10 mGy as compared to 2 mGy protocol (87.9 vs. 81.8%; p < 0.001). Stone size was significantly overestimated on all VNC compared to Man-M (7.0 ± 3.5 vs. 6.6 ± 2.8 mm, p < 0.001). Again, the 10 mGy protocol tended to show a better correlation with Man-M as compared to 2 mGy protocol (R<sup>2</sup> = 0.39-0.68 vs. R<sup>2</sup> = 0.31-0.57). Detection and size measurements of kidney stones surrounded by contrast media on VNC are feasible. The detection rate of kidney stones decreases with increasing iodine-induced attenuation and with decreasing radiation dose as well as stone size, while remaining comparable to CI<sub>0HU</sub> on VNC <sub>≤ 400 HU</sub>. • The detection rate of kidney stones on VNC depends on the surrounding iodine-induced attenuation, the used radiation dose, and the stone size. • The detection rate of kidney stones on VNC decreases with greater iodine-induced attenuation and with lower radiation dose, particularly in small stones. • The visibility of kidney stones on VNC <sub>≤ 400 HU</sub> remains comparable to true-non-contrast scans even when using a low-dose technique.

Medical subject headings