Comparison of the in-vivo kinematics of three different knee prosthesis designs during a step-up movement.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 36435077.
- Also identified by DOI 10.1016/j.clinbiomech.2022.105824.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
There is no consensus on the importance of the kinematics of the prosthetic joint for the clinical outcome after total knee arthroplasty. A 3-armed randomized controlled trial was done to determine and compare the in vivo kinematics of a posterior cruciate-retaining and two posterior cruciate-sacrificing (Anterior-Stabilized and Posterior-Stabilized) prosthetic designs from the same total knee arthroplasty system. Since the anterior-stabilized and posterior-stabilized designs are posterior cruciate ligament-sacrificing designs, we hypothesized they would have similar contact-point kinematics. Further, we hypothesized that the cruciate-retaining design would have contact-point kinematics different from the anterior-stabilized and the posterior-stabilized designs, but comparable to a native knee. Thirty-nine patients with a well-functioning total knee arthroplasty one year postoperatively underwent kinematic analysis of a weight-bearing step-up movement under fluoroscopic recording. Model-based radiostereometric analysis was used to determine anteroposterior contact-point translations and rotations through the movement path to assess knee kinematics. The cruciate-retaining and anterior-stabilized groups' medial and lateral contact-points displayed similar paradoxical posterior translations during step-up in the magnitude of 7 and 2 mm, respectively. In contrast, the posterior-stabilized group's contact-points translated anteriorly by 4 and 10 mm throughout the movement and were significantly more posterior than the cruciate-retaining and the anterior-stabilized groups from >100° to 40° of flexion. The femur rotated internally with all designs. The cruciate-retaining and anterior-stabilized designs displayed similar contact-point translation patterns during a step-up movement. Only the posterior-stabilized design showed a pattern comparable to native knees. Conversion from a cruciate-retaining to an anterior-stabilized design because of posterior cruciate ligament insufficiency will not change knee kinematics.
Medical subject headings
- Arthroplasty, Replacement, Knee
Anatomy
- knee