Patient-specific 3D printing to replace components of a rib-to pelvis "Eiffel Tower" vertebral expanding prosthetic titanium rib system in an infant: a case report.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 36436085.
- Also identified by DOI 10.1007/s00586-022-07460-z.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To address the anatomical challenges facing complex and revision spinal surgery, patient-specific 3D-printed models (3D-PMs) have received growing attention worldwide, primarily in adults. We report the use of a 3D-PM in the treatment of a case of wound breakdown over a component of a VEPTR (Vertical Expandable Prosthetic Titanium Rib; DePuy-Synthes) system, requiring replacement of Dunn-McCarthy hook and sleeve with components contoured to a patient-specific 3D-PM of the spine. A two-year-old born with myelomeningocele (MMC), repaired at birth, developed progressive MMC-associated kyphoscoliosis. Elective insertion of a rib-to-pelvis 'Eiffel Tower' bilateral VEPTR growing rods construct was performed without initial complication. Prominence of the right VEPTR sleeve and Dunn-McCarthy hook side-to-side connector resulted in breakdown of overlying poor-quality soft tissues, necessitating washout, partial implant removal, intravenous antibiotic therapy and delayed primary wound closure. A patient-specific 3D-PM, utilising pre-operative CT spine and pelvis 3D-reconstructions, allowed pre-operative formation of a contoured implant, which was inserted without need for further revision. The patient underwent further VEPTR lengthening without recurrent infection, wound breakdown or implant failure at 24-month follow-up. Satisfactory control of the deformity has been achieved with continued improvement in sitting height and radiographic indices. This case illustrates the possibility, in certain cases, of using 3D-PM to develop complex components of spinal implant systems pre-operatively, removing the time and difficulty of intra-operative contouring. Consequently, custom-contoured implants may be produced, sterilised and implanted. This technique may be an option, in infants, including MMC-associated kyphoscoliosis, where midline fixation is not possible.
Medical subject headings
- Titanium
- Scoliosis
Anatomy
- pelvis