Longitudinal analyses and predictive factors of radiation-induced lung toxicity-related parameters after stereotactic radiotherapy for lung cancer.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 36459528.
- Also identified by DOI 10.1371/journal.pone.0278707 and PMC identifier 9718403.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this prospective study was to investigate changes in longitudinal parameters after stereotactic radiotherapy for lung cancer and to identify possible pretreatment factors related to radiation-induced lung toxicity and the decline in pulmonary function after radiotherapy. Protocol-specified examinations, including 4-D CT, laboratory tests, pulmonary function tests (PFTs) and body composition measurements, were performed before SRT and at 1 month, 4 months and 12 months after stereotactic radiotherapy. Longitudinal differences were tested by using repeated-measures analysis of variance. Correlations were examined by using the Pearson product-moment correlation coefficient (r). Sixteen patients were analyzed in this study. During a median follow-up period of 26.6 months, grade 1 and 2 lung toxicity occurred in 11 patients and 1 patient, respectively. The mean Hounsfield units (HU) and standard deviation (SD) of the whole lung, as well as sialylated carbohydrate antigen KL-6 (KL-6) and surfactant protein-D (SP-D), peaked at 4 months after radiotherapy (p = 0.11, p<0.01, p = 0.04 and p<0.01, respectively). At 4 months, lung V20 Gy (%) and V40 Gy (%) were correlated with changes in SP-D, whereas changes in the mean HU of the lung were related to body mass index and lean body mass index (r = 0.54, p = 0.02; r = 0.57, p = 0.01; r = 0.69, p<0.01; and r = 0.69, p<0.01, respectively). The parameters of PFTs gradually declined over time. When regarding the change in PFTs from pretreatment to 12 months, lung V5 Gy (cc) showed significant correlations with diffusion capacity for carbon monoxide (DLCO), DLCO/alveolar volume and the relative change in DLCO (r = -0.72, p<0.01; r = -0.73, p<0.01; and r = -0.63, p = 0.01, respectively). The results indicated that some parameters peaked at 4 months, but PFTs were the lowest at 12 months. Significant correlations between lung V5 Gy (cc) and changes in DLCO and DLCO/alveolar volume were observed.
Medical subject headings
- Radiosurgery
- Lung Neoplasms
- Radiation Injuries