Assessment of epicardial adipose tissue on virtual non-contrast images derived from photon-counting detector coronary CTA datasets.

Risch, Franka; Schwarz, Florian; Braun, Franziska; Bette, Stefanie; Becker, Judith; Scheurig-Muenkler, Christian; Kroencke, Thomas J; Decker, Josua A · Eur Radiol · 2023

cross_sectional · Level IV

Where this comes from

Abstract

To assess epicardial adipose tissue (EAT) volume and attenuation of different virtual non-contrast (VNC) reconstructions derived from coronary CTA (CCTA) datasets of a photon-counting detector (PCD) CT-system to replace true non-contrast (TNC) series. Consecutive patients (n = 42) with clinically indicated CCTA and coronary TNC were included. Two VNC series were reconstructed, using a conventional (VNC<sub>Conv</sub>) and a novel calcium-preserving (VNC<sub>PC</sub>) algorithm. EAT was segmented on TNC, VNC<sub>Conv</sub>, VNC<sub>PC</sub>, and CCTA (CTA<sub>-30</sub>) series using thresholds of -190 to -30 HU and an additional segmentation on the CCTA series with an upper threshold of 0 HU (CTA<sub>0</sub>). EAT volumes and their histograms were assessed for each series. Linear regression was used to correlate EAT volumes and the Euclidian distance for histograms. The paired t-test and the Wilcoxon signed-rank test were used to assess differences for parametric and non-parametric data. EAT volumes from VNC and CCTA series showed significant differences compared to TNC (all p < .05), but excellent correlation (all R<sup>2</sup> > 0.9). Measurements on the novel VNC<sub>PC</sub> series showed the best correlation (R<sup>2</sup> = 0.99) and only minor absolute differences compared to TNC values. Mean volume differences were -12%, -3%, -13%, and +10% for VNC<sub>Conv</sub>, VNC<sub>PC</sub>, CTA<sub>-30</sub>, and CTA<sub>0</sub> compared to TNC. Distribution of CT values on VNC<sub>PC</sub> showed less difference to TNC than on VNC<sub>Conv</sub> (mean attenuation difference +7% vs. +2%; Euclidean distance of histograms 0.029 vs. 0.016). VNC<sub>PC</sub>-reconstructions of PCD-CCTA datasets can be used to reliably assess EAT volume with a high accuracy and only minor differences in CT values compared to TNC. Substitution of TNC would significantly decrease patient's radiation dose. • Measurement of epicardial adipose tissue (EAT) volume and attenuation are feasible on virtual non-contrast (VNC) series with excellent correlation to true non-contrast series (all R<sup>2</sup>>0.9). • Differences in VNC algorithms have a significant impact on EAT volume and CT attenuation values. • A novel VNC algorithm (VNC<sub>PC</sub>) enables reliable assessment of EAT volume and attenuation with superior accuracy compared to measurements on conventional VNC- and CCTA-series.

Medical subject headings