[<sup>68</sup>Ga]Ga-Pentixafor PET/CT imaging for in vivo CXCR4 receptor mapping in different lung cancer histologic sub-types: correlation with quantitative receptors' density by immunochemistry techniques.

Watts, Ankit; Singh, Baljinder; Singh, Harmandeep; Bal, Amanjit; Kaur, Harneet; Dhanota, Ninjit; Arora, Sunil K; Mittal, Bhagwant R et al. · Eur J Nucl Med Mol Imaging · 2023

prospective_cohort · Level II

Where this comes from

Abstract

In vivo CXCR4 receptor quantification in different lung cancer (LC) sub-types using [<sup>68</sup>Ga]Ga-Pentixafor PET/CT and to study correlation with quantitative CXCR4 receptors' tissue density by immunochemistry analyses. [<sup>68</sup>Ga]Ga-Pentixafor PET/CT imaging was performed prospectively in 94 (77 M: 17F, mean age 60.1 ± 10.1 years) LC patients. CXCR4 receptors' expression on lung mass in all the patients was estimated by immunohistochemistry (IHC) and fluorescence-activated cell sorting (FACS) analyses. SUV<sub>max</sub> on PET, intensity score on IHC, and mean fluorescence index (MFI) on FACS analyses were measured. A total of 75/94 (79.8%) cases had non-small cell lung cancer (NSCLC), 14 (14.9%) had small cell lung cancer (SCLC), and 5 (5.3%) had lung neuroendocrine neoplasm (NEN). All LC types showed increased CXCR4 expression on PET (SUV<sub>max</sub>) and FACS (MFI). However, both these parameters (mean SUV<sub>max</sub> = 10.3 ± 5.0; mean MFI = 349.0 ± 99.0) were significantly (p = 0.005) higher in SCLC as compared to those in NSCLC and lung NEN. The mean SUV<sub>max</sub> in adenocarcinoma (n = 16) was 8.0 ± 1.9 which was significantly (p = 0.003) higher than in squamous cell carcinoma (n = 54; 6.2 ± 2.1) and in not-otherwise specified (NOS) sub-types (n = 5; 5.8 ± 1.5) of NSCLC. A significant correlation (r = 0.697; p = 001) was seen between SUV<sub>max</sub> and MFI values in squamous cell NSCLC as well as in NSCLC adenocarcinoma (r = 0.538, p = 0.031) which supports the specific in vivo uptake of [<sup>68</sup>Ga]Ga-Pentixafor by CXCR4 receptors. However, this correlation was not significant in SCLC (r = 0.435, p = 0.121) and NEN (r = 0.747, p = 0.147) which may be due to the small sample size. [<sup>68</sup>Ga]Ga-Pentixafor PET/CT provided good sensitivity (85.7%) and specificity (78.1%) for differentiating SCLC from NSCLC (ROC cutoff SUV<sub>max</sub> = 7.2). This technique presented similar sensitivity (87.5%) and specificity (71.4%) (ROC cutoff SUV<sub>max</sub> = 6.7) for differentiating adenocarcinoma and squamous cell variants of NSCLC. The high sensitivity and specificity of [<sup>68</sup>Ga]Ga-Pentixafor PET/CT for in vivo targeting of CXCR4 receptors in lung cancer can thus be used effectively for the response assessment and development of CXCR4-based radioligand therapies in LC.

Medical subject headings