Association between sonographic sling location and success of surgery for stress urinary incontinence.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 36508434.
- Also identified by DOI 10.1002/uog.26142.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine the relationship between the clinical outcome of suburethral sling surgery for stress urinary incontinence and sling location on ultrasound examination. This was a retrospective study of patients diagnosed with stress urinary incontinence who were treated with a suburethral sling by a single surgeon between January 2009 and October 2016. Four-dimensional volumes acquired on transperineal ultrasound at least 3 months postoperatively were analyzed and the gap between the sling and symphysis pubis (sling-pubis gap (SPG)) on Valsalva maneuver was measured. Continence was assessed on a cough stress test at follow-up. A total of 378 patients were included, with a mean follow-up of 14.3 months. The success rate of sling surgery was 89.4%. The mean ± SD SPG on Valsalva maneuver was 12.0 ± 2.5 mm in women who were clinically continent at follow-up and 14.1 ± 2.8 mm in those with failed surgery (P < 0.001). A shorter SPG on transperineal ultrasound imaging after suburethral sling surgery is associated with cure of stress urinary incontinence. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
Medical subject headings
- Urinary Incontinence, Stress
- Suburethral Slings