Performance of a deep convolutional neural network for MRI-based vertebral body measurements and insufficiency fracture detection.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 36576545.
- Also identified by DOI 10.1007/s00330-022-09354-6 and PMC identifier 10121505.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
The aim is to validate the performance of a deep convolutional neural network (DCNN) for vertebral body measurements and insufficiency fracture detection on lumbar spine MRI. This retrospective analysis included 1000 vertebral bodies in 200 patients (age 75.2 ± 9.8 years) who underwent lumbar spine MRI at multiple institutions. 160/200 patients had ≥ one vertebral body insufficiency fracture, 40/200 had no fracture. The performance of the DCNN and that of two fellowship-trained musculoskeletal radiologists in vertebral body measurements (anterior/posterior height, extent of endplate concavity, vertebral angle) and evaluation for insufficiency fractures were compared. Statistics included (a) interobserver reliability metrics using intraclass correlation coefficient (ICC), kappa statistics, and Bland-Altman analysis, and (b) diagnostic performance metrics (sensitivity, specificity, accuracy). A statistically significant difference was accepted if the 95% confidence intervals did not overlap. The inter-reader agreement between radiologists and the DCNN was excellent for vertebral body measurements, with ICC values of > 0.94 for anterior and posterior vertebral height and vertebral angle, and good to excellent for superior and inferior endplate concavity with ICC values of 0.79-0.85. The performance of the DCNN in fracture detection yielded a sensitivity of 0.941 (0.903-0.968), specificity of 0.969 (0.954-0.980), and accuracy of 0.962 (0.948-0.973). The diagnostic performance of the DCNN was independent of the radiological institution (accuracy 0.964 vs. 0.960), type of MRI scanner (accuracy 0.957 vs. 0.964), and magnetic field strength (accuracy 0.966 vs. 0.957). A DCNN can achieve high diagnostic performance in vertebral body measurements and insufficiency fracture detection on heterogeneous lumbar spine MRI. • A DCNN has the potential for high diagnostic performance in measuring vertebral bodies and detecting insufficiency fractures of the lumbar spine.
Medical subject headings
- Fractures, Stress
- Spinal Fractures