Comparison of the Journey II bicruciate stabilised (JII-BCS) and GENESIS II total knee arthroplasty for functional ability and motor impairment: the CAPAbility, blinded, randomised controlled trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 36599639.
- Also identified by DOI 10.1136/bmjopen-2022-061648 and PMC identifier 9815016.
- Licence recorded as CC BY-NC.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To determine if a newer design of total knee replacement (TKR) (Journey II BCS) produces superior patient-reported outcomes scores and biomechanical outcomes than the older, more established design (Genesis II). Patients were recruited from an NHS University Hospital between July 2018 and October 2019 with surgery at two sites. Biomechanical and functional capacity measurements were at a University Movement and Exercise Laboratory. 80 participants undergoing single-stage TKR. Patients were randomised to receive either the Journey II BCS (JII-BCS) or Genesis II TKR. Primary outcome was the Oxford Knee Score (OKS), at 6 months. Secondary outcomes were: OKS Activity and Participation Questionnaire, EQ-5D-5L and UCLA Activity scores, Timed Up and Go Test, 6 min walk test, lower limb kinematics and lower limb muscle activity during walking and balance. This study found no difference in the OKS between groups. The OKS scores for the JII-BCS and Genesis II groups were mean (SD) 42.97 (5.21) and 43.13 (5.20) respectively, adjusted effect size 0.35 (-2.01,2.71) p=0.771In secondary outcome measures, the Genesis II group demonstrated a significantly greater walking range-of-movement (50.62 (7.33) vs 46.07 (7.71) degrees, adjusted effect size, 3.14 (0.61,5.68) p=0.02) and higher peak knee flexion angular velocity during walking (mean (SD) 307.69 (38.96) vs 330.38 (41.40) degrees/second, adjusted effect size was 21.75 (4.54,38.96), p=0.01) and better postural control (smaller resultant centre of path length) during quiet standing than the JII-BCS group (mean (SD) 158.14 (65.40) vs 235.48 (176.94) mm, adjusted effect size, 59.91 (-105.98, -13.85) p=0.01.). In this study population, the findings do not support the hypothesis that the Journey II BCS produces a better outcome than the Genesis II for the primary outcome of the OKS at 6 months after surgery. ISRCTN32315753.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Motor Disorders
- Osteoarthritis, Knee