Preliminary outcomes following revision total knee arthroplasty using a new fixed-bearing revision knee system in Asians: a mean of 3-year follow-up.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 36609383.
- Also identified by DOI 10.1186/s13018-023-03503-3 and PMC identifier 9817344.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
The purpose of this study was to investigate the early outcomes of the new semi-constrained revision total knee arthroplasty (TKA) system by performing subgroup analysis according to the revision cause. From August 2019 to July 2020, 83 revision TKAs using the fixed-bearing Attune® revision knee system with a minimum follow-up of 2 years were retrospectively reviewed. Clinically, the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, the Western Ontario and McMaster Universities Osteoarthritis Index, and range of motion (ROM) were evaluated. The incidence of systemic and specific postoperative complications was investigated. Each cohort was divided into septic (group A, 34 patients) and aseptic mode (group B, 41 patients), and compared to assess the outcomes. The mean age at the time of revision was 73.3 years (range 59.0 to 84.0 years), and the follow-up duration was 36.1 months (range 30.0 to 40.0 months). Clinical outcomes and ROM significantly improved at last follow-up (p < 0.001). Group A showed statistically inferior clinical outcomes in the last follow-up compared to group B. Four knees (5.3%) had a postoperative femoral joint line elevation of more than 5 mm. There were no serious systemic complications. One patient underwent re-revision TKA due to recurrence of infection. No stem tip impingement or cortical erosion was observed in all patients. Revision TKAs using a new semi-constrained revision system showed favorable short-term follow-up outcomes, with improvement in clinical scores and ROM. Moreover, by using stem offsets, no postoperative stem tip impingement or cortical erosion was found. Level IV, Retrospective Case Series.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Knee Prosthesis
- Osteoarthritis
Anatomy
- knee