Fitting mechanical properties of the aortic wall and individual layers to experimental tensile tests including residual stresses.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 36610281.
- Also identified by DOI 10.1016/j.jmbbm.2022.105647.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The authors have observed that a stress-strain curve for uniaxial tension of an aortic intact wall cannot be simply obtained by combining the strain energy functions of the three individual aortic layers - intima, media and adventitia - even taking into account the interaction among the three layers; the strain energy functions of the three layers are obtained fitting tensile tests on strips from the individual layers. Due to the layer separation, the residual stresses are released and thus they do not affect the stress-strain curves of the individual layers. The present study shows that it is instead possible to fit the intact wall experimental curves with the combination of the strain energy functions of the three individual layers if residual strains are added. The residual strains are used as optimization parameters with specific constraints and allowing for the buckling (wrinkling) of the intima under unpressurized condition of the aortic wall, as experimentally observed. By varying these parameters in the experimentally observed range of values, it is possible to find a solution with the combined responses of the individual layers matching the experimental stress-strain curves of the intact wall.
Medical subject headings
- Aorta
- Tunica Intima