Wide Variability in Dysplasia Detection Rate and Adherence to Seattle Protocol and Surveillance Recommendations in Barrett's Esophagus: A Population-Based Analysis Using the GIQuIC National Quality Benchmarking Registry.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 36623168.
- Also identified by DOI 10.14309/ajg.0000000000002102 and PMC identifier 10159981.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Variability in adherence rates to the Seattle protocol and to surveillance interval recommendations, established quality indicators (QIs) in Barrett's esophagus (BE), is unknown. We evaluated endoscopist and site-based adherence rates to these QIs from January 2018 to May 2021 using the GI Quality Improvement Consortium national registry with matched endoscopy and pathology data. Across 153 practices with 572 endoscopists performing 20,155 endoscopies, adherence to the Seattle protocol varied by endoscopists (median 93.8%, IQR 18.9%) and by site (median 90.0%, IQR 20.1%). Adherence to appropriate surveillance intervals for nondysplastic BE also varied by endoscopist (median 82.4%, IQR 36.3%) and site (median 77.2%, IQR 29.8%). The overall dysplasia detection rate was 3.1% and varied among endoscopists and sites. These US population-based results can serve as a benchmark for quality initiatives and intervention trials aimed at improving outcomes for patients with BE.
Medical subject headings
- Barrett Esophagus
- Esophageal Neoplasms