Robotic-guided direct transtemporal embolization of an indirect carotid cavernous fistula.

Karas, Patrick J; Lee, Jae Eun; Frank, Thomas S; Morden, Frances Tiffany; Shaltoni, Hashem; Kan, Peter · J Neurointerv Surg · 2023

case_report · Level V

Where this comes from

Abstract

A middle-aged patient presented with right-sided chemosis, exophthalmos, and progressive visual loss. Digital subtraction angiography revealed a type D carotid-cavernous fistula (CCF). Transarterial embolization through the internal maxillary artery was unsuccessful, and there was no venous access to the CCF. A robotic-guided direct transtemporal embolization of the CCF with Onyx was performed, resulting in successful fistula obliteration and symptom resolution. This is the first reported case of a robotic-guided direct transcranial CCF embolization. We include a technical video that demonstrates this procedure (Supplemental File 1).