Clinical and radiological outcome of the Chimaera short nailing system in inter- and subtrochanteric fractures.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 36646532.
- Also identified by DOI 10.1016/j.injury.2023.01.027.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
cephalomedullary devices are popular treatment for femoral intertrochanteric or subtrochanteric fractures. Various complications include post-surgical lateral thigh pain and cut-out. To prevent those complications, a new concept cephalomedullary device system was designed (Chimaera, Orthofix®). This study aimed to evaluate the clinical and radiological outcomes in patients with femoral intertrochanteric or subtrochanteric fractures treated with the proximal femoral cephalomedullary device system. A prospective cohort study involved consecutive patients with Arbeitsgemeinschaft für Osteosynthesefragen/ Orthopaedic Trauma Association type 31-A1, 2, 3 fractures treated with the Chimaera short cephalomedullary device system from October 2016 to September 2017 at our level 1 trauma center. The Parker and Palmer mobility score and Jensen social function scores and post-surgical lateral thigh pain were assessed at 3 months post-operatively and compared to before surgery. Radiologic assessment consisted of controlling the position of the cephalic screw by using the tip-apex distance (TAD) and Cleveland zone as well as union and cut-out rates. We included 99 patients (79 women; 100 hips; one bilateral fracture 3 months after a first trochanteric fracture) with a mean follow-up of 2 years. The Parker and Palmer mobility score decreased by 22% at 3 months post-operatively as compared with the pre-fracture score (42/99 patients showed a return to their pre-injury level). The Jensen social function score increased by 16.5% at 3 months post-operatively as compared with the pre-fracture score (68/99 patients showed a return to their pre-injury level). No major intra-operative complication was recorded. Nine TAD scores were > 25 mm. The mean TAD was 16.5 mm (range 5-36), and the lag screw position was well positioned in most (95%) hips according to Cleveland zones. Three patients required revision surgery (one for cut-out of the lag screw, one for hip osteoarthritis and one for gluteus medius insufficiency). All patients but the one with the cut-out showed fracture union. The Chimaera short cephalomedullary device exhibited good mid-term functional and radiological outcomes.
Medical subject headings
- Fracture Fixation, Intramedullary
- Hip Fractures