Alpha Defensin-1 Biomarker Outperforms Culture in Diagnosing Breast Implant-Related Infection: Results from a Multicenter Prospective Study.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 36729968.
- Also identified by DOI 10.1097/PRS.0000000000009982.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Prompt diagnosis of breast implant infection is critical to reducing morbidity. A high incidence of false-negative microbial culture mandates superior testing modalities. Alpha defensin-1 (AD-1), an infection biomarker, has outperformed culture in diagnosing periprosthetic joint infection with sensitivity/specificity of 97%. After previously demonstrating its feasibility in breast implant-related infection (BIRI), this case-control study compares the accuracy of AD-1 to microbial culture in suspected BIRI. An institutional review board-approved, prospective, multicenter study was conducted of adults with prior breast implant reconstruction undergoing surgery for suspected infection (cases) or prosthetic exchange/revision (controls). Demographics, perioperative characteristics, antibiotic exposure, and implant pocket fluid were collected. Fluid samples underwent microbial culture, AD-1 assay, and adjunctive markers (C-reactive protein, lactate, cell differential); diagnostic performance was assessed by means of sensitivity, specificity, and accuracy from receiver operating characteristic curve analysis, with values of P < 0.05 considered significant. Fifty-three implant pocket samples were included (cases, n = 20; controls, n = 33). All 20 patients with suspected BIRI exhibited cellulitis, 65% had abnormal drainage, and 55% were febrile. All suspected BIRIs were AD-1 positive (sensitivity, 100%). Microbial culture failed to grow any microorganisms in four BIRIs (sensitivity, 80%; P = 0.046); Gram stain was least accurate (sensitivity, 25%; P < 0.001). All tests demonstrated 100% specificity. Receiver operating characteristic curve analyses yielded the following areas under the curve: AD-1, 1.0; microbial culture, 0.90 ( P = 0.029); and Gram stain, 0.62 ( P < 0.001). Adjunctive markers were significantly higher among infections versus controls ( P < 0.001). Study findings confirm the accuracy of AD-1 in diagnosing BIRI and indicate superiority to microbial culture. Although further study is warranted, AD-1 may facilitate perioperative decision-making in BIRI management in a resource-efficient manner. Diagnostic, II.
Medical subject headings
- alpha-Defensins
- Breast Implants
- Prosthesis-Related Infections