Navigation assisted removal of a broken cannulated sacroiliac screw: A technical note.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 36764900.
- Also identified by DOI 10.1016/j.injury.2023.02.012.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Non-union of displaced pelvic ring injuries are challenging to treat. In cases where a previous osteosynthesis has failed it can be challenging to remove the previous implant. This technical note presents a technique for the removal of a broken SI screw in the sacrum. It is a navigation assisted technique that allows for minimal invasive screw remnant removal so that the sacral corridors remain available for later reconstruction.
Medical subject headings
- Pelvic Bones
- Surgery, Computer-Assisted
- Fractures, Bone