Despite a growing understanding of spinopelvic biomechanics in total hip arthroplasty (THA), there is no validated approach for executing patient-specific acetabular component positioning. The purpose of this study was to (1) validate quantitative, patient-specific acetabular "safe zone" component positioning from spinopelvic parameters and (2) characterize differences between quantitative patient-specific acetabular targets and qualitative hip-spine classification targets. From 2,457 consecutive primary THA patients, 22 (0.88%) underwent revision for instability. Spinopelvic parameters were measured prior to index THA. Acetabular position was measured following index and revision arthroplasty. Using a mathematical proof, we developed an open-source tool translating a surgeon-selected, preoperative standing acetabular target to a patient-specific safe zone intraoperative acetabular target. Difference between the patient-specific safe zone and the actual component position was compared before and after revision. Hip-spine classification targets were compared to patient-specific safe zone targets. Of the 22 who underwent revision, none dislocated at follow-up (4.6 [range, 1 to 6.9]). Patient-specific safe zone targets differed from prerevision acetabular component position by 9.1 ± 4.2° inclination/13.3 ± 6.7° version; after revision, the mean difference was 3.2 ± 3.0° inclination/5.3 ± 2.7° version. Differences between patient-specific safe zones and the median and extremes of recommended hip-spine classification targets were 2.2 ± 1.9° inclination/5.6 ± 3.7° version and 3.0 ± 2.3° inclination/7.9 ± 3.5° version, respectively. A mathematically derived, patient-specific approach accommodating spinopelvic biomechanics for acetabular component positioning was validated by approximating revised, now-stable hips within 5° version and 3° inclination. These patient-specific safe zones augment the hip-spine classification with prescriptive quantitative targets for nuanced preoperative planning.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
Anatomy
- hip
- pelvis