Interobserver Agreement Rates on C-X-C Motif Chemokine Receptor 4-Directed Molecular Imaging and Therapy.
Where this comes from
- Record sourced from PubMed, PMID 36947793.
- Also identified by DOI 10.1097/RLU.0000000000004629 and PMC identifier 10184817.
- Licence recorded as CC BY-NC-ND.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We aimed to evaluate the interobserver agreement rates in patients scanned with C-X-C motif chemokine receptor 4 (CXCR4)-directed PET/CT, including the rate of patients eligible for CXCR4-targeted radioligand therapy (RLT) based on scan results. Four independent observers reviewed 50 CXCR4-targeted [ 68 Ga]pentixafor PET/CT of patients with various solid cancers. On a visual level, the following items were assessed by each reader: overall scan impression, number of organ and lymph node (LN) metastases and number of affected organs and LN regions. For a quantitative investigation, readers had to choose a maximum of 3 target lesions, defined as largest in size and/or most intense uptake per organ compartment. Reference tissues were also quantified, including unaffected hepatic parenchyma and blood pool. Last, all observers had to decide whether patients were eligible for CXCR4-targeted RLT. Concordance rates were tested using intraclass correlation coefficients (ICCs). For interpretation, we applied the definition of Cicchetti (with 0.4-0.59 indicating fair; 0.6-0.74, good; 0.75-1, excellent agreement). On a visual level, fair agreement was achieved for an overall scan impression (ICC, 0.58; 95% confidence interval, 0.45-0.71). Organ and LN involvement (ICC, ≥0.4) demonstrated fair, whereas CXCR4 density and number of LN and organ metastases showed good agreement rates (ICC, ≥0.65). Number of affected organs and affected LN areas, however, showed excellent concordance (ICC, ≥0.76). Quantification in LN and organ lesions also provided excellent agreement rates (ICC, ≥0.92), whereas quantified uptake in reference organs provided fair concordance (ICC, ≥0.54). Again, excellent agreement rates were observed when deciding on patients eligible for CXCR4-RLT (ICC, 0.91; 95% confidence interval, 0.85-0.95). In patients scanned with CXCR4-targeted PET/CT, we observed fair to excellent agreement rates for both molecular imaging and therapy parameters, thereby favoring a more widespread adoption of [ 68 Ga]pentixafor in the clinic.
Medical subject headings
- Positron Emission Tomography Computed Tomography
- Coordination Complexes