Postoperative full leg radiographs exhibit less residual coronal varus deformity compared to intraoperative measurements in robotic arm-assisted total knee arthroplasty with the MAKO™ system.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 36964782.
- Also identified by DOI 10.1007/s00167-023-07386-z and PMC identifier 10435414.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Robotic arm-assisted total knee arthroplasty (raTKA), currently a major trend in knee arthroplasty, aims to improve the accuracy of implant positioning and limb alignment. However, it is unclear whether and to what extent manual radiographic and navigation measurements with the MAKO™ system correlate. Nonetheless, a high agreement would be crucial to reliably achieve the desired limb alignment. Thirty-six consecutive patients with osteoarthritis and a slight-to-moderate varus deformity undergoing raTKA were prospectively included in this study. Prior to surgery and at follow-up, a full leg radiograph (FLR) under weight-bearing conditions was performed. In addition, a computed tomography (CT) scan was conducted for preoperative planning. The hip-knee-ankle angle (HKA), mechanical lateral distal femur angle (mLDFA), mechanical medial proximal tibial angle (mMPTA) and joint line convergence angle (JLCA) were measured in the preoperative and follow-up FLR as well as in the CT scout (without weight-bearing) by three independent raters. Furthermore, the HKA was intraoperatively assessed with the MAKO™ system before and after raTKA. Significantly higher HKA values were identified for intraoperative deformity assessment using the MAKO system compared to the preoperative FLR and CT scouts (p = 0.006; p = 0.05). Intraoperative assessment of the HKA with final implants showed a mean residual varus deformity of 3.2° ± 1.9°, whereas a significantly lower residual varus deformity of 1.4° ± 1.9° was identified in the postoperative FLR (p < 0.001). The mMPTA was significantly higher in the preoperative FLR than in the CT scouts (p < 0.001). Intraoperatively, the mMPTA was adjusted to a mean of 87.5° ± 0.9° with final implants, while significantly higher values were measured in postoperative FLRs (p < 0.001). Concerning the mLDFA, no significant differences could be identified. The clinical importance of this study lies in the finding that there is a difference between residual varus deformity measured intraoperatively with the MAKO™ system and those measured in postoperative FLRs. This has implications for preoperative planning as well as intraoperative fine-tuning of the implant position during raTKA to avoid overcorrection of knees with slight-to-moderate varus osteoarthritis. Level IV.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Robotic Surgical Procedures
- Osteoarthritis, Knee
Anatomy
- knee
- tibia