Orthogonal plating of distal femur fractures: A biomechanical comparison with plate-nail and parallel plating constructs.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 36974099.
- Also identified by DOI 10.1016/j.jor.2023.02.003 and PMC identifier 10039308.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study compared the biomechanical properties of orthogonal plating with plate-nail and parallel plating constructs for supracondylar distal femur fractures. A supracondylar distal femur fracture was simulated using 15 synthetic osteoporotic femurs. Constructs included: (1) plate-nail (lateral locked distal femoral plate + retrograde intramedullary nail); (2) parallel plating (lateral locked distal femoral plate + medial 4.0 mm compression plate); and (3) orthogonal plating (lateral locked distal femoral plate + posterior one-third tubular plate). Specimens underwent nondestructive loading, fatigue loading, and loading to failure. Gapping at the fracture was measured using a three-dimensional motion capture system. Baseline torsional and axial stiffness, stiffness and strain after fatigue loading, and load to failure were determined. A case example of orthogonal plating is also presented. There was no difference in baseline torsional (p = 0.51) and axial stiffness (p = 0.53). Stiffness after fatigue loading was highest with parallel plating, with no difference between the plate-nail and orthogonal plating constructs (p = 0.84). Strain after fatigue loading was lowest in the parallel plating group (0.54 ± 0.19%), followed by the plate-nail (2.89 ± 0.83%) and orthogonal plating groups (3.04 ± 0.51%). Orthogonal plating demonstrated comparable baseline stiffness to plate-nail and parallel plating constructs, and similar biomechanical performance in fatigue loading to plate-nail constructs. All specimens had ≤3% strain after fatigue loading, suggesting sufficient stability for fracture healing. The benefits of enhanced stability from dual-implant fixation may be achieved through orthogonal plating while avoiding an additional medial surgical approach, and therefore warrants further investigation as a novel alternative for distal femur fracture fixation.
Anatomy
- femur