Two-year target vessel-related outcomes following use of off-the-shelf branched endografts for the treatment of thoracoabdominal aortic aneurysms.
Where this comes from
- Record sourced from PubMed, PMID 37044318.
- Also identified by DOI 10.1016/j.jvs.2023.03.498.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to assess clinical outcomes and target vessel patency through 2 years following thoracoabdominal aortic aneurysms (TAAA) repair with the off-the-shelf Zenith t-Branch Thoracoabdominal Endovascular Graft (William Cook Europe). This post-market observational study was conducted at three European sites with ambispective enrollment from 2012 to 2017. Patients underwent endovascular TAAA repair with the t-Branch graft and bridging stent grafts (BSGs) for the celiac (CA), superior mesenteric (SMA), left renal (LRA), and/or right renal (RRA) arteries. Follow-up was through 2 years, per sites' standard of care. Procedural and 1-year results were reported previously. Eighty patients (mean age, 71.0±7.4 years; 70.0% men) were enrolled; six patients had symptomatic TAAAs, and 15 patients had contained ruptures. Technical success was achieved in 98.8% of patients (79/80). Median follow-up was 22.2 months (interquartile range, 9.2-25.1 months). At 24 months, Kaplan-Meier (KM) freedom from all-cause and aneurysm-related mortality were 78.5% and 98.6%, respectively. Beyond 12 months, 38 adverse events occurred in 20 patients, including two aortic ruptures (one study aneurysm and one non-study aneurysm) and six deaths (none aneurysm-related, as reported by the site). Compared with postprocedure, maximum aneurysm diameter decreased (>5 mm) in 84.6% (44/52), remained unchanged in 3.8% (2/52), and increased (>5 mm) in 11.5% (6/52) of patients with imaging follow-up after 12 months. No conversions to open repair, and no t-Branch graft or other endograft component migration or integrity issues were reported. No loss of patency was reported in the t-Branch or iliac limb grafts throughout the study. Throughout study duration, four patients had five imaging-reported BSG compressions, none of which required secondary intervention. KM freedom from secondary intervention was 76.3% at 24 months. Fourteen target vessel-related secondary interventions were performed, primarily consisting of stent placement for endoleak, stenosis, or occlusion. KM freedom from loss of primary patency was 94.8%, 100%, 91.3%, and 89.3% for the CA, SMA, LRA, and RRA, respectively, at 24 months. KM freedom from loss of secondary patency in the CA, SMA, LRA, and RRA were 96.3%, 100%, 98.2%, and 98.3% at 24 months, respectively. A total of 298 vessels were targeted, of which 12 were occluded over the study period. Primary and secondary target vessel patency rates through 2 years demonstrated durable repair with the t-Branch graft in patients treated for symptomatic or asymptomatic thoracoabdominal aortic aneurysms.
Medical subject headings
- Aortic Aneurysm, Thoracoabdominal
- Blood Vessel Prosthesis Implantation
- Aortic Aneurysm, Thoracic
- Endovascular Procedures