Implementation of Video Laryngoscope-Assisted Coaching Reduces Adverse Tracheal Intubation-Associated Events in the PICU.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 37058348.
- Also identified by DOI 10.1097/CCM.0000000000005847.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate implementation of a video laryngoscope (VL) as a coaching device to reduce adverse tracheal intubation associated events (TIAEs). Prospective multicenter interventional quality improvement study. Ten PICUs in North America. Patients undergoing tracheal intubation in the PICU. VLs were implemented as coaching devices with standardized coaching language between 2016 and 2020. Laryngoscopists were encouraged to perform direct laryngoscopy with video images only available in real-time for experienced supervising clinician-coaches. The primary outcome was TIAEs. Secondary outcomes included severe TIAEs, severe hypoxemia (oxygen saturation < 80%), and first attempt success. Of 5,060 tracheal intubations, a VL was used in 3,580 (71%). VL use increased from baseline (29.7%) to implementation phase (89.4%; p < 0.001). VL use was associated with lower TIAEs (VL 336/3,580 [9.4%] vs standard laryngoscope [SL] 215/1,480 [14.5%]; absolute difference, 5.1%; 95% CI, 3.1-7.2%; p < 0.001). VL use was associated with lower severe TIAE rate (VL 3.9% vs SL 5.3%; p = 0.024), but not associated with a reduction in severe hypoxemia (VL 15.7% vs SL 16.4%; p = 0.58). VL use was associated with higher first attempt success (VL 71.8% vs SL 66.6%; p < 0.001). In the primary analysis after adjusting for site clustering, VL use was associated with lower adverse TIAEs (odds ratio [OR], 0.61; 95% CI, 0.46-0.81; p = 0.001). In secondary analyses, VL use was not significantly associated with severe TIAEs (OR, 0.72; 95% CI, 0.44-1.19; p = 0.20), severe hypoxemia (OR, 0.95; 95% CI, 0.73-1.25; p = 0.734), or first attempt success (OR, 1.28; 95% CI, 0.98-1.67; p = 0.073). After further controlling for patient and provider characteristics, VL use was independently associated with a lower TIAE rate (adjusted OR, 0.65; 95% CI, 0.49-0.86; p = 0.003). Implementation of VL-assisted coaching achieved a high level of adherence across the PICUs. VL use was associated with reduced adverse TIAEs.
Medical subject headings
- Laryngoscopes
- Mentoring