Failure to Normalize Biventricular Function Is Associated with Extracorporeal Membrane Oxygenation Use in Neonates with Congenital Diaphragmatic Hernia.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 37201678.
- Also identified by DOI 10.1016/j.jpeds.2023.113490.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We examined postnatal echocardiograms for 62 infants with congenital diaphragmatic hernia born from 2014 through 2020. Left and right ventricular dysfunction on D0 were sensitive, whereas persistent dysfunction on D2 was specific for extracorporeal membrane oxygenation requirement. Biventricular dysfunction had the strongest association with extracorporeal membrane oxygenation. Serial echocardiography may inform prognosis in congenital diaphragmatic hernia.
Medical subject headings
- Hernias, Diaphragmatic, Congenital
- Extracorporeal Membrane Oxygenation