Management of Mechanical Prosthetic Heart Valve Thrombosis: JACC Review Topic of the Week.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 37225366.
- Also identified by DOI 10.1016/j.jacc.2023.03.412.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Mechanical prosthetic heart valves, though more durable than bioprostheses, are more thrombogenic and require lifelong anticoagulation. Mechanical valve dysfunction can be caused by 4 main phenomena: 1) thrombosis; 2) fibrotic pannus ingrowth; 3) degeneration; and 4) endocarditis. Mechanical valve thrombosis (MVT) is a known complication with clinical presentation ranging from incidental imaging finding to cardiogenic shock. Thus, a high index of suspicion and expedited evaluation are essential. Multimodality imaging, including echocardiography, cine-fluoroscopy, and computed tomography, is commonly used to diagnose MVT and follow treatment response. Although surgery is oftentimes required for obstructive MVT, other guideline-recommended therapies include parenteral anticoagulation and thrombolysis. Transcatheter manipulation of stuck mechanical valve leaflet is another treatment option for those with contraindications to thrombolytic therapy or prohibitive surgical risk or as a bridge to surgery. The optimal strategy depends on degree of valve obstruction and the patient's comorbidities and hemodynamic status on presentation.
Medical subject headings
- Thrombosis
- Bioprosthesis
- Heart Valve Prosthesis