Evaluation of anterior translation in total knee arthroplasty utilizing stress radiographs.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 37264460.
- Also identified by DOI 10.1186/s13018-023-03862-x and PMC identifier 10233901.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Flexion instability is a common cause for revision after total knee arthroplasty (TKA); however, little objective criteria exist to determine excessive laxity in flexion. This study sought to determine the reliability of stress radiographs for flexion laxity using manual stress as well as a commercially available flexion stress device, with the hypothesis that a commercially available force device would provide increased translation compared to manual stress, and radiographic measurements would be reproducible. Ten patients who previously underwent TKA with non-hinged components were prospectively and consecutively enrolled at a single center to undergo stress radiographs. Three lateral radiographs with the knee at 90° of flexion were obtained for each patient: rest, commercial stress device at 150N, and manual stress. Calibrated radiographs were evaluated by two raters, and inter-rater and intra-rater reliability were determined using intraclass correlation coefficients (ICC). Ten patients (seven female) with mean age 72 (range 55-82) years and average duration from surgery 36 (range 12-96) months were evaluated. The commercial stress device provided significantly less anterior translation than manual stress (- 0.3 mm vs. 3.9 mm; p < 0.01). Two patients reported pain with use of the stress device. Inter-observer reliability of measurements was good for commercial stress (ICC = 0.86) and excellent for manual stress (ICC = 0.94). Eighty-five percent of measurements were within 1 mm between observers. Intra-observer reliability of measurements was good to excellent for both the stress device and manual stress. Lateral stress radiographs may assist in the objective evaluation of flexion instability. A commercially available product provided less translation than manual stress; however, measurements were reliable and reproducible between observers. Further research is required to correlate translation with stress radiographs to patient outcomes following revision arthroplasty.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Joint Instability
Anatomy
- knee