Sequential Active Contour Based on Morphological-Driven Thresholding for Ultrasound Image Segmentation of Ascites.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 37335794.
- Also identified by DOI 10.1109/JBHI.2023.3286869.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Paracentesis is a high-demanding and routine operation, which has great potentials and benefits if semi-autonomous procedures can be developed. One of the most important techniques that facilitate semi-autonomous paracentesis is to segment the ascites from ultrasound images accurately and efficiently. The ascites, however, is usually with significantly different shapes and noise among different patients, and its shape/size changes dynamically during the paracentesis. This makes most of existing image segmentation methods either time consuming or inaccurate for segmenting ascites from its background. In this article, we propose a two-stage active contour method to facilitate accurate and efficient segmentation of ascites. First, a morphological-driven thresholding method is developed to locate the initial contour of the ascites automatically. Then, the identified initial contour is fed into a novel sequential active contour algorithm to segment the ascites from background accurately. The proposed method is tested and compared with state-of-the-art active contour methods on over 100 real ultrasound images of ascites, and the results show the superiority of our method in both accuracy and time efficiency.
Medical subject headings
- Ascites
- Algorithms