To compare preoperative magnetic resonance imaging (MRI) and intraoperative measurements of labral width and determine whether MRI can reliably predict labral width in the setting of revision surgery. Patients who underwent revision hip arthroscopy with labral repair performed by a single surgeon from January 2008 to December 2015 were identified retrospectively from a prospectively collected database. The width of the labrum was measured intraoperatively at the time of surgery. Two orthopaedic surgeons performed labral width measurements on MRI scans at 3 standardized locations using the clock-face method. Interobserver and intraobserver reliabilities were calculated, and comparisons between intraoperatively measured labral widths and MRI measurements were performed. Fifty-eight patients who underwent revision hip arthroscopy were enrolled in the study. The average labral width measurements at the 3-, 12-, and 9-o'clock positions were 7.4 mm (standard deviation [SD], 1.2 mm), 7.5 mm (SD, 1.4 mm), and 6.6 mm (SD, 1.2 mm), respectively, on MRI compared with 6.7 mm (SD, 2.1 mm), 6.5 mm (SD, 2.5 mm), and 7.0 mm (SD, 1.9 mm), respectively, when measured intraoperatively. The average intraoperative measurements were smaller than the MRI measurements at the 3-o'clock (P = .03) and 12-o'clock (P = .01) positions. The inter-rater intraclass correlation coefficients between the 2 surgeons exhibited good agreement (0.612) at the 3-o'clock position, fair agreement (0.498) at the 12-o'clock position, and poor agreement (0.171) at the 9-o'clock position. The positive predictive values of the MRI measurements were 72% at the 3-o'clock position, 68% at the 12-o'clock position, and 88% at the 9-o'clock position for identifying a labral width of 6 mm or greater. The results of this study show that MRI-measured labral width and actual labral width measured at the time of revision arthroscopy are usually within 1 mm of each other. Level II, diagnostic study investigating diagnostic test.
Medical subject headings
- Arthroscopy
- Magnetic Resonance Imaging
Anatomy
- hip