Efficacy of Near-Infrared Fluorescence Video-Assisted Thoracoscopic Surgery for Small Pulmonary Nodule Resection with Indocyanine Green Inhalation: A Randomized Clinical Trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 37389655.
- Also identified by DOI 10.1245/s10434-023-13753-4 and PMC identifier 8169305.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
BACKGROUND: Small pulmonary nodules (<3 cm) can sometimes be unrecognizable and nonpalpable in video-assisted thoracoscopic surgery (VATS). Near-infrared fluorescence (NIF) VATS after indocyanine green (ICG) inhalation may effectively guide surgeons to locate the nodules. OBJECTIVE: This study aimed to investigate the safety, feasibility, and efficacy of ICG inhalation-based NIF imaging for guiding small pulmonary nodule resections. METHODS: Between February and May 2021, the first-stage, non-randomized trial enrolled 21 patients with different nodule depth, ICG inhalation doses, post-inhalation surgery times, and nodule types at a tertiary referral hospital. Between May 2021 and May 2022, the second-stage randomized trial enrolled 56 patients, who were randomly assigned to the fluorescence VATS (FLVATS) or the white-light VATS (WLVATS) group. The ratio of effective guidance and the time consumption for nodule localization were compared. RESULTS: The first-stage trial proved this new method is safe and feasible, and established a standardized protocol with optimized nodule depth (≤1 cm), ICG dose (0.20-0.25 mg/kg), and surgery window (50-90 min after ICG inhalation). In the second-stage trial, the FLVATS achieved 87.1% helpful nodule localization guidance, which was significantly higher than the WLVATS (59.1%, p < 0.05). The mean nodule locating time (standard deviation) was 1.8 [0.9] and 3.3 [2.3] min, respectively. Surgeons adopting FLVATS were significantly faster (p < 0.01), especially when locating small ground-glass opacities (1.3 [0.6] min vs. 7.0 [3.5] min, p < 0.05). Five of 31 nodules (16.1%) were only detectable by FLVATS, whereas both white light and palpation failed. CONCLUSIONS: This new method is safe and feasible for small pulmonary nodule resection. It significantly improves nodule localization rates with less time consumption, and hence is highly worthy for clinical promotion. Clinical Trial Registration Chinese Clinical Trial Registry Identifier: ChiCTR2100047326.