Evaluation of proton density fat fraction (PDFF) obtained from a vendor-neutral MRI sequence and MRQuantif software.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 37402003.
- Also identified by DOI 10.1007/s00330-023-09798-4.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To validate the proton density fat fraction (PDFF) obtained by the MRQuantif software from 2D chemical shift encoded MR (CSE-MR) data in comparison with the histological steatosis data. This study, pooling data from 3 prospective studies spread over time between January 2007 and July 2020, analyzed 445 patients who underwent 2D CSE-MR and liver biopsy. MR derived liver iron concentration (MR-LIC) and PDFF was calculated using the MRQuantif software. The histological standard steatosis score (SS) served as reference. In order to get a value more comparable to PDFF, histomorphometry fat fraction (HFF) were centrally determined for 281 patients. Spearman correlation and the Bland and Altman method were used for comparison. Strong correlations were found between PDFF and SS (r<sub>s</sub> = 0.84, p < 0.001) or HFF (r<sub>s</sub> = 0.87, p < 0.001). Spearman's coefficients increased to 0.88 (n = 324) and 0.94 (n = 202) when selecting only the patients without liver iron overload. The Bland and Altman analysis between PDFF and HFF found a mean bias of 5.4% ± 5.7 [95% CI 4.7, 6.1]. The mean bias was 4.7% ± 3.7 [95% CI 4.2, 5.3] and 7.1% ± 8.8 [95% CI 5.2, 9.0] for the patients without and with liver iron overload, respectively. The PDFF obtained by MRQuantif from a 2D CSE-MR sequence is highly correlated with the steatosis score and very close to the fat fraction estimated by histomorphometry. Liver iron overload reduced the performance of steatosis quantification and joint quantification is recommended. This device-independent method can be particularly useful for multicenter studies. The quantification of liver steatosis using a vendor-neutral 2D chemical-shift MR sequence, processed by MRQuantif, is well correlated to steatosis score and histomorphometric fat fraction obtained from biopsy, whatever the magnetic field and the MR device used. • The PDFF measured by MRQuantif from 2D CSE-MR sequence data is highly correlated to hepatic steatosis. • Steatosis quantification performance is reduced in case of significant hepatic iron overload. • This vendor-neutral method may allow consistent estimation of PDFF in multicenter studies.
Medical subject headings
- Fatty Liver
- Iron Overload
- Non-alcoholic Fatty Liver Disease