Lymphography using microbubbles and contrast-enhanced ultrasound (CEUS) before lymphatic supermicrosurgery for severe lymphorrhea of lower extremity.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 37421677.
- Also identified by DOI 10.1016/j.bjps.2023.06.031.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Lymphaticovenous anastomosis (LVA) is an effective surgical treatment for lymphorrhea. However, the traditional indocyanine green (ICG) fluorescent lymphography mapping for lymphatic vessels has limitations, it can only depict the initial capillary lymphatic network localized in the dermis of the skin, which cannot visualize lymphatics deeper than 1.5 cm. A new mapping technique, microbubbles and contrast-enhanced ultrasound (CEUS) can address the problem. In one case of lymphocutaneous fistula, for the first time, we used microbubbles and CEUS technique for preoperative localization for LVAs. Microbubbles and CEUS can identify deep lymphatic vessels and better evaluate the function of lymphatic vessels. The patient's symptoms of edema and lymphorrhea improved clinically. Microbubbles and CEUS is an effective methods for identifying lymphatic vessels in lower limbs.
Medical subject headings
- Lymphedema
- Lymphatic Diseases
- Lymphatic Vessels