Assessing the Feasibility of Using Artificial Intelligence-Segmented Dominant Intraprostatic Lesion for Focal Intraprostatic Boost With External Beam Radiation Therapy.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 37517600.
- Also identified by DOI 10.1016/j.ijrobp.2023.07.029.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The delineation of dominant intraprostatic gross tumor volumes (GTVs) on multiparametric magnetic resonance imaging (mpMRI) can be subject to interobserver variability. We evaluated whether deep learning artificial intelligence (AI)-segmented GTVs can provide a similar degree of intraprostatic boosting with external beam radiation therapy (EBRT) as radiation oncologist (RO)-delineated GTVs. We identified 124 patients who underwent mpMRI followed by EBRT between 2010 and 2013. A reference GTV was delineated by an RO and approved by a board-certified radiologist. We trained an AI algorithm for GTV delineation on 89 patients, and tested the algorithm on 35 patients, each with at least 1 PI-RADS (Prostate Imaging Reporting and Data System) 4 or 5 lesion (46 total lesions). We then asked 5 additional ROs to independently delineate GTVs on the test set. We compared lesion detectability and geometric accuracy of the GTVs from AI and 5 ROs against the reference GTV. Then, we generated EBRT plans (77 Gy prostate) that boosted each observer-specific GTV to 95 Gy. We compared reference GTV dose (D98%) across observers using a mixed-effects model. On a lesion level, AI GTV exhibited a sensitivity of 82.6% and positive predictive value of 86.4%. Respective ranges among the 5 RO GTVs were 84.8% to 95.7% and 95.1% to 100.0%. Among 30 GTVs mutually identified by all observers, no significant differences in Dice coefficient were detected between AI and any of the 5 ROs. Across all patients, only 2 of 5 ROs had a reference GTV D98% that significantly differed from that of AI by 2.56 Gy (P = .02) and 3.20 Gy (P = .003). The presence of false-negative (-5.97 Gy; P < .001) but not false-positive (P = .24) lesions was associated with reference GTV D98%. AI-segmented GTVs demonstrate potential for intraprostatic boosting, although the degree of boosting may be adversely affected by false-negative lesions. Prospective review of AI-segmented GTVs remains essential.
Medical subject headings
- Magnetic Resonance Imaging
- Prostatic Neoplasms