Feasibility of acquisitions using total-body PET/CT with a half-dose [<sup>68</sup>Ga]Ga-FAPI-04 activity in oncology patients.

Chen, Zijun; Wang, Yining; Yang, Xinlan; Li, Lianghua; Huo, Yanmiao; Yu, Xiaofeng; Xiao, Xiuying; Zhang, Chenpeng et al. · Eur J Nucl Med Mol Imaging · 2023

prospective_cohort · Level II

Where this comes from

Abstract

[<sup>68</sup>Ga]Ga-FAPI-04 (gallium-68-labeled fibroblast activation protein inhibitor-04) PET/CT has been widely used in diagnosing malignant tumors. Total-body PET/CT has a long axial field of view and provides higher sensitivity compared to traditional PET/CT. However, whether the reduced injected dose of [<sup>68</sup>Ga]Ga-FAPI-04 could obtain qualified imaging has not been evaluated. To explore the effect of half-dose [<sup>68</sup>Ga]Ga-FAPI-04 on image quality and tumor detectability in oncology patients. A total of twenty-seven patients with tumors or clinically suspected tumors were included, and all patients were scanned with total-body PET/CT after an injected dose of 0.84-1.14 MBq/kg [<sup>68</sup>Ga]Ga-FAPI-04. All patients obtained superior image quality with 300 s original acquisition time. Images were reconstructed using 180 s, 120 s, 60 s, 40 s, 30 s, 20 s scanning duration by ordered subset expectation maximization algorithm. The subjective image quality of all patients in each time group was scored using 5-point Likert scale. Mediastinal blood pool, liver, spleen, and muscle were analyzed as background using semi-quantitative parameters maximum standardized uptake values (SUV<sub>max</sub>), mean standardized uptake values (SUV<sub>mean</sub>), standard deviation (SD), and signal to noise ratio (SNR). The lesion detection rate, SUV<sub>max</sub>, and tumor-to-background ratio (TBR) were calculated for tumors confirmed by pathology. The subjective image quality score decreased with the shortening of scanning time; however, both 180 s and 120 s images met the diagnostic requirements in terms of overall quality, lesion conspicuity, and image noise. The SUV<sub>max</sub> of background increased with the reduction of scanning time, while the SUV<sub>mean</sub> was relatively stable. With the shortening of scanning time, the SD gradually increased, and the SNR gradually decreased, which was consistent with subjective image quality scores. In 180 s and 120 s images, all 11 primary lesions and 79 metastatic lesions were detected. The SUV<sub>max</sub> of tumor focus showed an increasing trend as same as the background. Compared with 300 s, the TBR muscle had no statistical difference in 180 s and 120 s. Half-dose [<sup>68</sup>Ga]Ga-FAPI-04 in total-body PET/CT imaging can shorten the acquisition time to 120 s with acceptable subjective image quality and 100% tumor detection rate. Total-body PET/CT imaging with a half-dose [<sup>68</sup>Ga]Ga-FAPI-04 and reduced acquisition time can be used in radiation-sensitive and poor tolerant to prolong horizontal positioning and waiting time populations such as children and gravidas.

Medical subject headings