Which Bone Mineral Density Measure Offers a More Reliable Prediction of Mechanical Complications in Adult Spinal Deformity Surgery: Hounsfield Units or DEXA Scan?

Chanbour, Hani; Chen, Jeffrey W; Vaughan, Wilson E; Abtahi, Amir M; Gardocki, Raymond J; Stephens, Byron F; Zuckerman, Scott L · World Neurosurg · 2023

retrospective_cohort · Level III

Where this comes from

Abstract

In patients undergoing adult spinal deformity (ASD) surgery, we sought to: (1) determine the relationship between dual-energy x-ray absorptiometry (DEXA)-measured bone mineral density (BMD), T-scores, and Hounsfield units (HU), and (2) compare the ability of DEXA-measured BMD, T-scores, and HU to predict mechanical complications and reoperations. A single-institution retrospective cohort study was undertaken for cases from 2013 to 2017. ≥5-level-fusion, sagittal/coronal deformity, and 2-year follow-up. Multivariable regression controlled for age, body mass index, receiving anabolic medications, and postoperative sagittal vertical axis and pelvic-incidence lumbar-lordosis mismatch. A subanalysis was performed for osteopenic patients (-1 < T-score < -2). Of 145 patients undergoing ASD surgery, 72 (49.6%) had both preoperative DEXA and computed tomography scans. Mean DEXA-measured BMD was 0.91 ± 0.52 g/cm<sup>2</sup>, mean T-score was -1.61 ± 1.03, and mean HU was 153.5 ± 52.8. While no correlation was found between DEXA-measured BMD and HU (r = 0.17, P = 0.144), T-score and HU had a weakly positive correlation (r = 0.31, P = 0.007). Mechanical complications occurred in 48 (66.7%) patients, including 27 (37.5%) proximal junctional kyphosis (PJK), 1 (1.4%) distal junctional kyphosis, 5 (6.9%) implant failure, 30 (41.7%) rod fracture/pseudarthrosis, 42 (58.3%) reoperations, and 16 (22.2%) reoperations due to PJK. No association was found between DEXA-measured BMD or T-scores with mechanical complications or reoperations. While univariate regression showed a significant association between lower HU and PJK (OR 0.98, 95%CI 0.97-0.99, P = 0.011), the significance was lost after multivariable analysis. When considering osteopenic patients (n = 37), only DEXA-measured BMD was an independent risk factor for PJK (OR 0.01, 95%CI 0.00-0.09, P = 0.017), with a threshold of 0.82 g/cm<sup>2</sup> (AUC 0.70, 95%CI 0.53-0.84, P = 0.019). Poor correlation was found between the 3 BMD modalities. DEXA-measured BMD may be superior to T-scores and HU in predicting PJK among patients with osteopenia with a threshold of BMD <0.82 g/cm<sup>2</sup>.

Medical subject headings