Evaluating Firefighter On-Scene Decontamination Practices Using a National Fire Records Management System.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 37550953.
- Also identified by DOI 10.1097/JOM.0000000000002927 and PMC identifier 10662600.
- Licence recorded as CC BY-NC-ND.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study describes firefighters' on-scene decontamination procedure use post-working fire and frequency of adherence to best practice. This retrospective analysis of working fires was conducted using records from the ESO Data Collaborative (Austin, TX) national research database from January 1, 2021, to December 31, 2021. Documentation of decontamination procedures was examined among records with smoke or combustion products exposure. Firefighter and incident characteristics were evaluated. Descriptive statistics and univariable odds ratios were calculated. Among the 31,281 firefighters included in the study, 8.0% documented a fire-related exposure. Of those, 82% performed at least one on-scene decontamination procedure; 5% documented all decontamination procedures defined as best practices. The odds of documenting any decontamination procedure were significantly decreased among firefighters responding to incidents in rural areas compared with urban areas (odds ratio, 0.70). Fire personnel may not be taking all necessary decontamination steps post-working fires.
Medical subject headings
- Firefighters
- Fires
- Occupational Exposure