Predictors of 5-Year Mortality in Patients Managed With a Magnetically Levitated Left Ventricular Assist Device.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 37612008.
- Also identified by DOI 10.1016/j.jacc.2023.05.066.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In advanced heart failure patients implanted with a fully magnetically levitated HeartMate 3 (HM3, Abbott) left ventricular assist device (LVAD), it is unknown how preimplant factors and postimplant index hospitalization events influence 5-year mortality in those able to be discharged. The goal was to identify risk predictors of mortality through 5 years among HM3 LVAD recipients conditional on discharge from index hospitalization in the MOMENTUM 3 pivotal trial. This analysis evaluated 485 of 515 (94%) patients discharged after implantation of the HM3 LVAD. Preimplant (baseline), implant surgery, and index hospitalization characteristics were analyzed individually, and as multivariable predictors for mortality risk through 5 years. Cumulative 5-year mortality in the cohort (median age: 62 years, 80% male, 65% White, 61% destination therapy due to transplant ineligibility) was 38%. Two preimplant characteristics (elevated blood urea nitrogen and prior coronary artery bypass graft or valve procedure) and 3 postimplant characteristics (hemocompatibility-related adverse events, ventricular arrhythmias, and estimated glomerular filtration rate <60 mL/min/1.73 m<sup>2</sup> at discharge) were predictors of 5-year mortality. In 171 of 485 patients (35.3%) without any risk predictors, 5-year mortality was reduced to 22.6% (95% CI: 15.4%-32.7%). Even among those with 1 or more predictors, mortality was <50% at 5 years (45.7% [95% CI: 39.0%-52.8%]). Long-term survival in successfully discharged HM3 LVAD recipients is largely influenced by clinical events experienced during the index surgical hospitalization in tandem with baseline factors, with mortality of <50% at 5 years. In patients without identified predictors of risk, long-term 5-year mortality is low and rivals that achieved with heart transplantation, even though most were implanted with destination therapy intent. (MOMENTUM 3 IDE Clinical Study Protocol, NCT02224755; MOMENTUM 3 Pivotal Cohort Extended Follow-up PAS, NCT03982979).
Medical subject headings
- Heart Failure
- Heart-Assist Devices