Do working length and proximal screw density influence the velocity of callus formation in distal tibia fractures treated with a medial bridge plate?

Gilli, Antonio; Ghirardelli, Stefano; Pozzi, Pierrenzo; Touloupakis, Georgios; Messori, Matteo; Theodorakis, Emmanouil; Antonini, Guido · Eur J Orthop Surg Traumatol · 2024

retrospective_cohort · Level III

Where this comes from

Abstract

Aim of our study was to evaluate the influence of working length and screw density on callus formation in distal tibial fractures fixed with a medial bridge plate. 42 distal tibia fractures treated with a bridge plate were analyzed. Minimum follow-up was 12 months. mRUST score (modified Radiographic Union Scale for Tibial fractures) was used to assess callus formation. Working length and screw density were  measured from post-operative radiographs. 39 (92.9%) fractures healed uneventfully. 32 (76.19%) patients showed signs of early callus formation 3 months post-surgery. In these patients a lower screw density was used compared to patients who didn't show early callus (33.4 vs. 26.6; p = 0.04). No differences was noticed in working length. Bridge plate osteosynthesis is a good treatment option in distal tibia fractures. In our series increasing the working length was not associated with a faster callus formation in distal tibia fractures. Conversely, a lower screw density proximally to the fracture site was associated to a faster callus growth.

Medical subject headings

Anatomy