Comparison of finite helical axis of the knee joint before and after bi-cruciate-preserving knee arthroplasty.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 37729737.
- Also identified by DOI 10.1016/j.clinbiomech.2023.106098.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Difference in the finite helical axis of the knee joints before and after anterior cruciate ligament-preserving knee arthroplasties such as unicompartmental knee arthroplasty and bi-cruciate-retaining total knee arthroplasty remains unknown. This study compared the knee finite helical axes before and after bi-cruciate-preserving knee arthroplasty. Patients undergoing medial unicompartmental knee arthroplasty and bi-cruciate-retaining total knee arthroplasty were included. Under fluoroscopy, participants performed a deep knee bend before and after surgery. A two/three-dimensional registration technique was employed to measure tibiofemoral kinematics. Femoral finite helical axis was calculated in a flexion range of 0-120° using 30° windows (early-, mid-, late-, and deep-flexion phases). In unicompartmental knee arthroplasty, the preoperative knee vertical angle was larger than the postoperative vertical angle in mid- and deep-flexion phases. The postoperative knee vertical angle was smaller in unicompartmental knee arthroplasty than in bi-cruciate-retaining total knee arthroplasty. In unicompartmental knee arthroplasty, the preoperative horizontal angle was smaller than the postoperative horizontal angle in the early-flexion phase. However, in bi-cruciate-retaining total knee arthroplasty, the preoperative horizontal angle was larger than the postoperative horizontal angle in mid- and deep-flexion phases. The horizontal angle was smaller before unicompartmental knee arthroplasty than that before bi-cruciate-retaining total knee arthroplasty in early-, mid-, and deep-flexion phases. However, the vertical angle was larger after unicompartmental knee arthroplasty than that after bi-cruciate-retaining total knee arthroplasty in the early-flexion phase. The knee finite helical axes before and after unicompartmental knee arthroplasty differed from those before and after bi-cruciate-retaining total knee arthroplasty.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Osteoarthritis, Knee
- Knee Prosthesis
Anatomy
- knee