Long-term results of the Aptis<sup>TM</sup> total distal radioulnar joint prosthesis after previous failed surgical procedures.

Martínez Villén, Gregorio; Espada Blasco, Carlos; Rodríguez Nogué, Luis; García González, Elena · J Hand Surg Eur Vol · 2024

case_series · Level IV

Where this comes from

Abstract

We present a prospective study with the results of ten Aptis total distal radioulnar joint replacements in patients who had one to five previous operations. The mean postoperative follow-up was 9.7 years (range 3-14.7). The mean postoperative range of motion of the wrist improved by 9° for extension, 15° for flexion, 10° for pronation and 14° for supination, achieving values equivalent to 88%, 78%, 97% and 88% of those of the non-operated hand. There were minimal changes in radial and ulnar deviations. Grip strength improved by 7 kg, pain decreased by 8 points, QuickDASH and Mayo wrist scores improved by 51 and 53 points, respectively. Two implants had radiolucency less than 1 mm. Serum titanium ion levels were slightly elevated in two patients. Three prostheses required revision surgery for heterotopic ossification, a prominent radial screw and a periprosthetic fracture. No prostheses were removed. Six patients returned to their former professional activities and four patients adapted their jobs.<b>Level of evidence:</b> IV.

Medical subject headings

Anatomy