Magnon Confinement in an All-on-Chip YIG Cavity Resonator Using Hybrid YIG/Py Magnon Barriers.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 37819876.
- Also identified by DOI 10.1021/acs.nanolett.3c02388 and PMC identifier 10603800.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Confining magnons in cavities can introduce new functionalities to magnonic devices, enabling future magnonic structures to emulate the established photonic and electronic components. As a proof-of-concept, we report magnon confinement in a lithographically defined all-on-chip YIG cavity created between two YIG/Permalloy bilayers. We take advantage of the modified magnetic properties of the covered/uncovered YIG film to define on-chip distinct regions with boundaries capable of confining magnons. We confirm this by measuring multiple spin-pumping voltage peaks in a 400 nm wide platinum strip placed along the center of the cavity. These peaks coincide with multiple spin-wave resonance modes calculated for a YIG slab with the corresponding geometry. The fabrication of micrometer-sized YIG cavities following this technique represents a new approach to control coherent magnons, while the spin-pumping voltage in a nanometer-sized Pt strip demonstrates to be a noninvasive local detector of the magnon resonance intensity.