The Development of a Thick-Lens Post-Myopic Laser Vision Correction Intraocular Lens Calculation Formula.

Debellemanière, Guillaume; Mechleb, Nicole; Bernier, Timothée; Ancel, Jean-Marc; Gauvin, Mathieu; Wallerstein, Avi; Saad, Alain; Gatinel, Damien · Am J Ophthalmol · 2024

case_series · Level IV

Where this comes from

Abstract

To describe the development of the post-myopic laser vision correction (LVC) version of the PEARL-DGS intraocular lens (IOL) calculation formula and to evaluate its outcomes on an independent test set. Retrospective, single-center case series. A modified lens position prediction algorithm was designed along with methods to predict the posterior corneal curvature radius and correct the corneal power measurement error. A different set of previously operated eyes that underwent LVC was used to evaluate the prediction precision of the post-LVC formula. Post-LVC PEARL-DGS formula significantly reduced mean absolute error of prediction in comparison to Haigis-L, Shammas, and American Society of Cataract and Refractive Surgery (ASCRS) average formulas (P < .001). It exhibited similar postoperative refractive precision as the Barrett True-K No History formula (P = .61). The post-LVC formula development process described in this article performed as well as the state-of-the-art post-LVC formula on the present test set. Further studies are required to assess its efficacy in other independent sets.

Medical subject headings