The role of advanced metal artifact reduction MRI in the diagnosis of periprosthetic joint infection.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 37875571.
- Also identified by DOI 10.1007/s00256-023-04483-5 and PMC identifier 11039568.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Identification and diagnosis of periprosthetic joint infection (PJI) are challenging, requiring a multi-disciplinary approach involving clinical evaluation, laboratory tests, and imaging studies. MRI is advantageous to alternative imaging techniques due to superior soft tissue contrast and absence of ionizing radiation. However, the presence of metallic implants can cause signal loss and artifacts. Metal artifact suppression (MARS) MRI techniques have been developed that mitigate metal artifacts and improve periprosthetic soft tissue visualization. This paper provides a review of the various MARS MRI techniques, their clinical applicability and accuracy in PJI diagnosis and evaluation, and current challenges and future perspectives.
Medical subject headings
- Artifacts
- Prosthesis-Related Infections
- Magnetic Resonance Imaging
- Metals