The Biomechanics of the Transpedicular Endoscopic Approach.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 37942817.
- Also identified by DOI 10.1097/BRS.0000000000004871 and PMC identifier 11232940.
- Licence recorded as CC BY-NC-ND.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Biomechanical cadaveric study. The goal of this study was to analyze the effects of an endoscopic transpedicular approach with different drill diameters (6 and 8 mm) and compare them with the intact native side. In addition, the influence of bone quality on the resistance of the pedicle was investigated. Clinical studies have repeatedly highlighted the benefits of endoscopic transpedicular decompression for downmigrated lumbar disc herniations. However, the biomechanical effects on pedicle stability have not been studied up to now. Twenty-four vertebras originating from four fresh-frozen cadavers were tested under uniaxial compression load in a ramp-to-failure test: (1) the tunneled pedicle on one side, and (2) the native pedicle on the other side. Twelve lumbar vertebrae were assigned to drill diameter of 6 mm and the other 12 to diameter of 8 mm. The median ratio of sustained force for the operated side compared with the intact contralateral side is equal to 74% (63-88) for both drill diameters combined. An 8 mm transpedicular approach recorded an axial resistance of 77% (60-88) compared with the intact contralateral side ( P =0.002). A 6 mm approach resulted in an axial resistance of 72% (66-84) compared with the intact opposite side ( P =0.01). No significant difference between the two different drill diameters was recorded ( P =1). For all three subgroups (intact, 8 mm, 6 mm) the Hounsfield units-values and the absolute resistance force showed significant correlations (intact: ρ=0.859; P <0.001; 8 mm: ρ=0.902; P <0.001; 6 mm: ρ=0.835; P <0.001). The transpedicular approach significantly reduces the axial resistance force of the pedicle, which may lead to pedicle fracture. Bone quality correlated positively with the absolute resistance force of the pedicle, whereas the influence of the drill hole diameter plays only a limited role.
Medical subject headings
- Lumbar Vertebrae
- Endoscopy
- Cadaver
Anatomy
- lumbar spine