Evaluation of pragmatic oxygenation measurement as a proxy for Covid-19 severity.
Where this comes from
- Record sourced from PubMed, PMID 37968269.
- Also identified by DOI 10.1038/s41467-023-42205-6 and PMC identifier 10651917.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
Choosing optimal outcome measures maximizes statistical power, accelerates discovery and improves reliability in early-phase trials. We devised and evaluated a modification to a pragmatic measure of oxygenation function, the [Formula: see text] ratio. Because of the ceiling effect in oxyhaemoglobin saturation, [Formula: see text] ratio ceases to reflect pulmonary oxygenation function at high [Formula: see text] values. We found that the correlation of [Formula: see text] with the reference standard ([Formula: see text]/[Formula: see text] ratio) improves substantially when excluding [Formula: see text] and refer to this measure as [Formula: see text]. Using observational data from 39,765 hospitalised COVID-19 patients, we demonstrate that [Formula: see text] is predictive of mortality, and compare the sample sizes required for trials using four different outcome measures. We show that a significant difference in outcome could be detected with the smallest sample size using [Formula: see text]. We demonstrate that [Formula: see text] is an effective intermediate outcome measure in COVID-19. It is a non-invasive measurement, representative of disease severity and provides greater statistical power.
Medical subject headings
- COVID-19