Safe Ultrasonography-Assisted Knee Posterior Transseptal Portal Creation Technique.
expert_opinion · Level V
Where this comes from
- Record sourced from PubMed, PMID 38094949.
- Also identified by DOI 10.1016/j.eats.2023.07.001 and PMC identifier 10714212.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Knee arthroscopy is a minimally invasive surgical technique that allows surgeons to diagnose and treat various knee conditions using much smaller incisions than open surgery. However, it is difficult to fully visualize the posterior compartment of the knee joint using the usual anterior portal approach because of blind spots. The transseptal portal technique enables surgeons to visualize the surgical field and access instruments in the posterior compartment of the knee during arthroscopic surgery. However, creation of the posterior transseptal portal increases the risk of neurovascular injury. Particular attention should be paid to avoid damaging the saphenous nerve, common peroneal nerve, popliteal artery, and tibial nerve. Here, we describe an ultrasonography-guided surgical method for creating the posterior transseptal portal by confirming the surrounding anatomy.
Anatomy
- knee